نمایشگر VU وات و دسیبل سیستم های صوتی با بک لایت LED مدل TN-90
قیمت : 92,400 تومان
در انبار موجود نمی باشد
برچسب: صوت
توضیحات
Description:
Pointers Material: Zinc and copper-nickel alloy
Pointer color: orange
The direction of the pointer swing : left to right
Pointer length : 44± 1 mm from the center axis to the needle end
Pointer width : 0.45 ± 0.05 mm
Electrical Characteristics:
standard test conditions temperature: 20 ℃, humidity 70% . Can also be tested under normal temperature and humidity
The influenza degree pointer at the zero scale to the maximum scale sensitivity of 960uA ± 8% (full scale position)
internal impedance :650Ω ± 10%
Insulation impedance meter outside the box plus the electrical circuit with 500V DC plus 50M ohm meter shell
Electrical insulation of the circuit impedance is 500V DC voltage test of the insulation value. Pointer to overlap with the zero-scale tolerance of ± 1mm balanced meter using a standard position and tilt 90 degrees to allow the error range of ± 1mm
pointer to mount the current instant plus three times the full scale current, and slowly reduced to the the electric influenza degree 1/2 reading,
The pointer will return to the scale plate within 1/3 scale friction meter coupled with the current, and slowly increase or decrease to a certain value, indicating the point of error range of ± 1mm,
brake instantly plus scale plate 2/3 of the current value of the pointer indicates the location of the time required for a second or less.
Special test
tests on each interval of five seconds to ten times the full scale current input overload, the action is repeated nine times for each time of 0.5 secondsAfter this test, 7-14 to maintain normal.
vibration test meter packaged in the vibration plate 1,000 times per minute, up and down 4mm shock In each direction for 10 minutes. After this test 7-14 to maintain normal impact test meter packaged 30-cm height of fall in 3cm thick wooden board, XYZ three-direction test.After this test, 7-14 to maintain normal reliability test the current input of 100,000 calibration points within the limits of current sense is still the standard environmental impact test temperature of 50 ° C, humidity 85%, for 100 hours, after this test 7-14 to maintain normal.
terminal pull test :terminals must withstand one kilogram tension, sustained 60 seconds will not be affected.
Others:
using the temperature limits :-10 ℃ to +60 ℃ RH 35 to 85%
Storage temperature limits :-20 ℃ to +60 ℃ RH 35 to 85%
توضیحات تکمیلی
جنس عقربه ها | آلیاژ روی و مس-نیکل |
---|---|
رنگ عقربه | نارنجی |
جهت نوسان عقربه | چپ به راست |
طول عقربه | 44±1 میلی متر از مرکز تا انتهای عقربه |
عرض عقربه | 0.45±0.05 میلی متر |
دما در شرایط تست اساندارد | ℃ 20، رطوبت 70%. |
نقد وبررسی
نقد بررسی یافت نشد...